2. Remove the cover from the fender-mounted intake duct.
3. Loosen the clamp, disconnect the air intake duct from the air flow meter.
4. Disconnect the high-voltage wiring for the ignition coil and distributor, and the power transistor wiring, and release the clip securing the wiring harness to the air flow meter hanger.
5. Unscrew the air filter housing and air flow meter hanger from the inner wing panel (five screws or bolts) and remove the assembly, disconnect the air flow meter wiring connector (photo). Remove the air filter housing and air flow meter.
66.5C. Air Flow Meter Connector - Lower Unit
6. You can unscrew the air flow meter if required.
7. Installation is carried out in reverse order.