Checked contacts and resistance (at room temperature):
- Contacts 8 (+), 7 (-): not O or infinity Σ
- Contacts 8 (-), 7 (+): not O or infinity Σ
- Contacts 5 (+), 8 (-): not O or infinity Σ
- Contacts 5 (-), 8 (+): infinity Σ
- Contacts 7 (+), 5 (-): infinity Σ
- Contacts 7 (-), 5 (+): O or not infinity Σ
When measured with a digital tester, the resistance values will differ from those indicated.
Check if power is supplied from the distributor (rotor and distributor cap).
If resistance values differ from norm, replace the distributor.